Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Environ Sci Technol ; 55(1): 488-498, 2021 01 05.
Article in English | MEDLINE | ID: covidwho-962234

ABSTRACT

Wastewater-based epidemiology may be useful for informing public health response to viral diseases like COVID-19 caused by SARS-CoV-2. We quantified SARS-CoV-2 RNA in wastewater influent and primary settled solids in two wastewater treatment plants to inform the preanalytical and analytical approaches and to assess whether influent or solids harbored more viral targets. The primary settled solids samples resulted in higher SARS-CoV-2 detection frequencies than the corresponding influent samples. Likewise, SARS-CoV-2 RNA was more readily detected in solids using one-step digital droplet (dd)RT-PCR than with two-step RT-QPCR and two-step ddRT-PCR, likely owing to reduced inhibition with the one-step ddRT-PCR assay. We subsequently analyzed a longitudinal time series of 89 settled solids samples from a single plant for SARS-CoV-2 RNA as well as coronavirus recovery (bovine coronavirus) and fecal strength (pepper mild mottle virus) controls. SARS-CoV-2 RNA targets N1 and N2 concentrations correlated positively and significantly with COVID-19 clinically confirmed case counts in the sewershed. Together, the results demonstrate that measuring SARS-CoV-2 RNA concentrations in settled solids may be a more sensitive approach than measuring SARS-CoV-2 in influent.


Subject(s)
COVID-19 , Coronavirus Infections , Animals , Cattle , Coronaviridae , Humans , RNA , RNA, Viral/genetics , SARS-CoV-2 , Wastewater
2.
Emerg Infect Dis ; 27(1)2021 Jan.
Article in English | MEDLINE | ID: covidwho-922785

ABSTRACT

Pooled nucleic acid amplification tests for severe acute respiratory syndrome coronavirus 2 could increase availability of testing at decreased cost. However, the effect of dilution on analytical sensitivity through sample pooling has not been well characterized. We tested 1,648 prospectively pooled specimens by using 3 nucleic acid amplification tests for severe acute respiratory syndrome coronavirus 2: a laboratory-developed real-time reverse transcription PCR targeting the envelope gene, and 2 commercially available Panther System assays targeting open reading frame 1ab. Positive percent agreement (PPA) of pooled versus individual testing ranged from 71.7% to 82.6% for pools of 8 and from 82.9% to 100.0% for pools of 4. We developed and validated an independent stochastic simulation model to estimate effects of dilution on PPA and efficiency of a 2-stage pooled real-time reverse transcription PCR testing algorithm. PPA was dependent on the proportion of tests with positive results, cycle threshold distribution, and assay limit of detection.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/isolation & purification , COVID-19/virology , Clinical Laboratory Techniques/methods , False Negative Reactions , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/standards , Prospective Studies , SARS-CoV-2/genetics , Sensitivity and Specificity , Specimen Handling , Stochastic Processes
SELECTION OF CITATIONS
SEARCH DETAIL